Converting your D1 control board to the EGA control board


Remove the D1 control board from the main control box and secure the EGA control board as show in the image.

You are provided with screw 3 holes to secure the control board to the main control box (see red arrows in photo). If you only have 2 screws from your D1 control board, use 1 screw to secure the top section of the control board and the other screw in either of the bottom 2 screw holes.

Now you can wire up your actuator arm, accessories and power.

Please see wiring instructions below:

Wiring Instructions

Electric Gate Lock

Setting up your Electric Gate Lock

Menu Settings

To enter the Menu settings, the gate/s must be in either the full Open or full Close position, the control board will not allow you to enter the Menu settings while the gate opener is operating.

Press and hold “FUN” button for 2 seconds or until the Digital Display shows P0. From here use “DEC” or “INC” buttons to go down or up the menu list, once you are on the menu setting you need, press “FUN” button once to enter the setting. Now use “DEC” or “INC” to decrease or increase the parameter number, once you have selected the parameter number you require, press the “FUN” button to confirm the new setting.

To exit the menu setting, press the “Learn” button once.
Now test your adjusted settings.

Learning Your Gate with the EGA Control Board

Double swing gates

Dual swing AUTO TRAVEL LEARN procedure:

ENSURE THE GATE WAY ENTRANCE IS CLEAR OR ANY OBSTRUCTIONS.

To perform the ‘AUTO TRAVEL LEARN’ function, you will need to activate your gate opener with a remote. Press Button A for 2 seconds or until the small LED light on the remote flickers orange, now release Button A on the remote. You should observe “OP” appearing on the Digital Display “MENU”.

For a dual swing gate, the “MENU” will show OP to say the control board has put Motor 1 gate into an OPEN position, the “MENU” will then show SP to say the control board has turned Motor 1 off.

The “MENU” will repeat this sequence for Motor 2. With the control board now knowing your gates are in the open position, you will need to press the DEC and INC buttons at the same time for 5 seconds (you must press and hold in both buttons at the same time for this to work, pressing the buttons individually first will not allow the control board to run its ‘AUTO TRAVEL LEARN’ function).

The gate connected to Motor 1 will close first, the “MENU” will display CL (Close), after Motor 1 has closed the gate, the “MENU” will display SP (Stop). Motor 2 will now close with the “MENU” displaying CL (Close), after Motor 2 has closed the gate, the “MENU” will display SP (Stop).

1 to 2 seconds after Motor 2 has closed the gate it will activate again with the “MENU displaying OP (Open), after Motor 2 has opened the gate, the “MENU” will display SP (Stop). Motor 1 will now open the gate with the “MENU” displaying OP (Open), once the gate is open the “MENU” will display SP (Stop). Wait 10 seconds before operating the gate opener.

Press Button A on your remote for 2 seconds or until the orange LED light starts to flicker and then release the button. Check that your gates operate correctly. Check if your force settings need to be adjusted. If they require adjusting, please refer to the MENU settings to adjust. Majority of gates won’t require any adjustments.

Single swing gate

Single swing AUTO TRAVEL LEARN procedure:

ENSURE THE GATE WAY ENTRANCE IS CLEAR OR ANY OBSTRUCTIONS.

To perform the ‘AUTO TRAVEL LEARN’ function, you will need to activate your gate opener with a remote. Press Button A for 2 seconds or until the small LED light on the remote flickers orange, now release Button A on the remote. You should observe “OP” appearing on the Digital Display “MENU”.

For a Single swing gate, the “MENU” will show OP to say the control board has put Motor 2 gate into an OPEN position, the “MENU” will then show SP to say the control board has turned Motor 2 off.

With the control board now knowing your gate is in the open position, you will need to press the DEC and INC buttons at the same time for 5 seconds (you must press and hold in both buttons at the same time for this to work, pressing the buttons individually first will not allow the control board to run its ‘AUTO TRAVEL LEARN’ function).

The gate Motor 2 will now close with the “MENU” displaying CL (Close), after Motor 2 has closed the gate, the “MENU” will display SP (Stop). 1 to 2 seconds after Motor 2 has closed the gate it will activate again with the “MENU displaying OP (Open), after Motor 2 has opened the gate, the “MENU” will display SP (Stop). Wait 10 seconds before operating the gate opener.

Press Button A on your remote for 2 seconds or until the orange LED light starts to flicker, then release the button. Check that your gate operates correctly. Check if your force settings need to be adjusted. If they require adjusting, please refer to the MENU settings to adjust. Majority of gates won’t require any adjustments.