Eyebeams - wired - DACE
Wired Safety Beams Instructions:
1. Indicators:
- The Transmitter is fitted with a RED LED which indicates when the power is on.
- The receiver is fitted with a RED LED which indicates when the beams are aligned.
2. Manufacturers Comments:
- It is recommended that beams be sealed with silicone rubber once they are closed.
- Beams can be affected by florescent lights. It is not recommended that the beams be placed in direct view of florescent pillar lights.
- The range of the beams can be affected by environmental conditions. Rain, mist etc can reduce the range of the beams.
- Ensure that the power is disconnected before wiring the beams.
3. Fitting Beams to the Gate Post:
- Beams should be placed around 700mm high above the ground level. The transmitter and receiver must, however, be aligned along a visual (and level) axis.
- If aligning the beams over a distance greater than 20m it is necessary that the covers be replaced in order to achieve alignment.
- Remove the PC Boards from both transmitter and receiver units.
- Place the housing backing against the pillar at the prescribed spot and scribe through the screw holes.
- Drill at the scribed marks using a 5mm masonry drill.
- Attach the housing backing to the wall using the supplied fasteners and 'O' ring. Ensure that the 'O' ring is fitted to the top fastener.
- Replace the PC Boards and follow wiring instructions as per gate motor manual or BMGs wiring guides below.
4. Technical Specifications:
- Power Supply: 12V-24V DC/AC
- Max. Distance: 40m
- Output Contact Rating: 5A at 220V AC








